TECHNICAL DATA |

Reverse side of unit
|
Network |
IEEE 802.3 - 10BaseT (*) |
Network connection |
1 x RJ45 socket (*) |
Protocols |
CP/IP, HTTPS, DHCP, SMTP, SSL 128-bit, RSA 1024-bit (*) |
User name / password protection |
User-definable names, up to 60 characters
- One administrator
- Up to 255 user profiles, each with user-definable access to each power
outlet and each group |
Device Names |
A name can be assigned to each ePowerSwitch (master and satellites). Each consumer (socket) also has a user-defined name. |
Groups |
Up to 255 groups definable with names. Any assignment of sockets (consumers). |
Event-based actions |
|
Triggers |
- Failure of one of the master’s three power supplies
or one of the two satellites’ power supplies
- Failure of ping or port scans of an IP address
(Guard function)
- Closing or opening one of the eight input contacts
- Scheduler time and weekday
- Breaching of min. and max. thermometer
or moisture meter readings |
Actions |
One or more of the following actions can be triggered:
- Switching a device and/or group on or off
or restarting after a user-definable delay
- Closing, opening or pulsing an output contact
with adjustable duration
- Sending a log entry to the Syslog server
- sending a message to up to two recipients
|
Temperature and humidity sensors |
Up to four sensors can be connected at any point on the bus. |
Connector |
2 x RJ12 6P6C socket |
Measured range |
-40 to +100°C +/- 2°C
0 to 50°C +/- 1°C
0 to 100% rel. humidity +/- 5%
20 to 80% rel. humidity +/- 3% |
Switched inputs/outputs |
D-Sub socket, 25-pin
Optional I/O extension module with quick-release terminals |
Inputs |
Eight inputs for switching contacts (approx. 2 mA) |
Outputs |
Four floating output relays (max. 24 volt, 20 mA) |
Displays |
Master:
- LEDs for network connection, traffic, 10/100 status.
- LED for server status
- One LED each for switched inputs/outputs
Master and satellites:
- One LED each for the two 230 volt power supplies
- One LED each for the switching state of each socket |
Expansion through
X Control Bus |
Up to 16 16 satellites can be connected to each master. Low-interference
RS 485 interface. |
Connector |
2 x RJ12 6P6C socket (one each on master and satellite) |
Cabling |
CAT3 or higher (at least 6 strands) |
Total length |
Max. 200 metres; depending on environment also longer |
Serial interface |
Master and satellite: V.24 D-Sub socket, 9-pin |
Scheduler/clock |
Highly accurate, battery-backed crystal clock, synchronizable through
a primary and a secondary NTP server. Automatic summer time (DST) changeover
selectable. |
Connectors
230 Volt |
IEC 320 (inlet connector for non-heating devices) |
Mains connection |
2 x socket |
Consumer connection |
8 x plug |
Switching current (max.) |
2 x 10 A per device (master and slave) |
per device (master and satellit) |
20 A. 10 A each for the two separate circuits |
per consumer |
10 A continuous current
120 A peak current |
Fuse |
2 x 10 A, time-lag |
Controller power supply |
Redundant, through one or both connected power supplies. Automatic changeover. |
Auxiliary power
(Master only) |
Additional power supply for maintaining logging, e-mail notification,
etc.
12 volt DC, approx. 300 mA; - low-voltage socket for PSU or battery. |
Voltage range |
200 to 250 V |
Operating temperature |
0 to 50 °C |
Humidity |
10 to 80 %, non-condensing |
Dimensions |
19" 1 height unit – 437 x 107 x 42 mm (w x d x h) |
Weight |
2 kg master, 2 kg slave |
Enclosure |
Metal |